Etek Overcurrent Protection Low Voltage Breakers ETL5
Description
- Overview
- Product Description
- Certifications
- Techinical Data
- Packaging & Shipping
- After Sales Service
- About Us
- Our Partners & Exhibitions
- FAQ
Basic Info.
| Model NO. | ETL5-63B-3P+N-50A |
| Speed | Normal Type Circuit Breaker |
| Arc-extinguishing Medium | Air |
| Installation | 35mm DIN Rail |
| Structure | RCBO |
| Poles Number | 3p+N |
| Type | Circuit Breaker |
| Function | Overcurrent Protection, Short Circuit Protection |
| Type of Trip | Thermal-Magnetic |
| Rated Breaking Capacity | 10ka |
| Stndard | IEC61009-1/IEC62423 |
| Residual Current Type | B |
| Transport Package | Carton |
| Specification | 39.5*22.5*25.5 |
| Trademark | ETEK / OEM |
| Origin | Zhejiang, Prc |
Packaging & Delivery
Package Size39.50cm * 22.50cm * 25.50cm Package Gross Weight15.300kgProduct Description
Product DescriptionETL5-63B Residual Current Circuit Breaker with Overcurrent ProtectionETL5-63B Type B RCBO (Residual Current Circuit Breaker with Overcurrent protection) is a combined protective device that integrates residual current protection (RCD) and overcurrent protection (MCB), with a rated current up to 63A. It supports single-phase 230/240V and three-phase 400/415V systems, features a 10kA breaking capacity, and meets IEC61009-1 and IEC62423 standards.
Type B RCBOs are specifically designed to detect smooth DC residual currents, as well as AC and pulsating DC currents. This makes them ideal for applications such as industrial environments with variable speed drives, solar panel systems, EV charging stations, commercial distribution boards, and residential installations where enhanced earth leakage protection is required.
| General Data | |
| Standard | IEC/EN 61009-1, IEC/EN 62423 |
| Type of trip | Ground fault, Overcurrent and short circuit |
| Ground fault: Electronic, Overload and short circuit: Thermal-magnetic | |
| Residual current type | B Type - residual AC, pulsating and smooth DC current, high frequency (≤1kHz) |
| No. of poles | 1P+N (3 modules), 3P+N (5modules, with switched neutral) |
| Insulation voltage (Ui) | 500V |
| Rated voltage (Ue) | 1P+N: 230/240V~; 3P+N: 400/415V~ |
| Rated currents (In) | 6, 10, 16, 20, 25, 32, 40, 50, 63A |
| Rated sensitivity current (IΔn) | 30, 100, 300mA |
| Rated current off-time under (IΔn) | ≤0.1s |
| Rated residual making and breaking capacity (IΔm) | 500A (In≤50A), 10In (In>50A) |
| Rated frequency | 50/60Hz |
| Rated short-circuit capacity (Icn) | 10kA |
| Energy limiting class | 3 |
| Rated impulse withstand voltage (Uimp) (1.2/50μs) | 4kV |
| Dielectric test voltage | 2.5kV (50/60Hz, 1min.) |
| Fire resistance (glow-wire test) | 960±15°C (Enclosure); 650±10°C (Handle) |
| Thermal tripping characteristics | 1.13In No tripping within an hour; 1.45In Tripping within an hour |
| Instantaneous tripping characteristics | B: 3In-5In; C: 5In-10In; D: 10In-20In |
| Electrical life | 4,000 Cycles |
| Mechanical life | 10,000 Cycles |
| Contact position indication | green OFF / red ON |
| Protection degree | IP20 |
| Ambient temperature | -25°C ~ +55°C, Max.95% humidity |
| Terminal connection type | Line side terminals: Cable/ Pin-type/ Fork-type busbar Load side terminals: Cable/ Pin-type |
| Max. terminal size for cable | 16mm² flexible/ 25mm² rigid |
| Max. tightening torque | 2.5N.m |
| Mounting type | Mounting on 35mm DIN rail |
| Incoming method | From top |
| Tripping Sensitivity | |
| 30mA | This is the most commonly used protection level in homes and commercial buildings, and is suitable for socket protection in general residential environments, offices and commercial places. |
| 100mA | Usually used in situations where personal protection requirements are not as strict as 30mA, or for equipment protection such as air conditioning systems, industrial equipment, etc. |
| 300mA | Mainly used for fire protection, such as distribution boards and the general protection of large electrical equipment. |
| Tripping times | |||||
| Type B RCDs - Standard values of break me and non-actuating time for residual direct currents which result from rectifying circuits and for residual smooth direct current. | |||||
| Type | Fault currents | Tripping time at | |||
| Alternating currents | 1×IΔn | 2×IΔn | 5×IΔn | 500A | |
| Pulsating DC currents | 1.4×IΔn | 2×1.4×IΔn | 5×1.4×IΔn | 500A | |
| Smooth DC currents | 2×IΔn | 2×2×IΔn | 5×2×IΔn | 500A | |
| Standard | Max. 0.3s | Max. 0.15s | Max. 0.04s | Max. 0.04s | |
| Type B RCDs - Residual non-opera ng and opera ng current according to frequencies which differ from the rated frequency 50/60 Hz | ||
| Frequency (Hz) | Residual non-operating current (IΔn) | Residual operating current (IΔn) |
| 150 | 0.5 IΔn | 2.4 IΔn |
| 400 | 0.5 IΔn | 6 IΔn |
| 1000 | IΔn | 14 IΔn |
| Tripping Characteristics | |||||||
| Curve | Rated current | Thermal Release | Magnetic Release | ||||
| Non-trip | Trip | Non-trip time | Hold current | Trip current | Trip time | ||
| B | 6-63A | 1.13In | ≤1h | 3In | ≥0.1 | ||
| 1.45In | <1h | 5In | <0.1 | ||||
| C | 6-63A | 1.13In | ≤1h | 5In | ≥0.1 | ||
| 1.45In | <1h | 10In | <0.1 | ||||
| D | 6-63A | 1.13In | ≤1h | 10In | ≥0.1 | ||
| 1.45In | <1h | 20In | <0.1 | ||||


Prev: Andeli MCB Adb3