ETL2
Overview Package Size50.40cm * 26.00cm * 17.00cm Package Gross Weight10.500kg .lc-a-img { position: relative; width: 100
Description
- Overview
- Product Description
- Certifications
- Techinical Data
- Packaging & Shipping
- After Sales Service
- About Us
- Our Partners & Exhibitions
- FAQ
Basic Info.
| Model NO. | ETL2-63-1P+N-50A |
| Speed | Normal Type Circuit Breaker |
| Arc-extinguishing Medium | Air |
| Installation | 35mm DIN Rail |
| Structure | RCBO |
| Poles Number | 1p+N |
| Type | Circuit Breaker |
| Function | Overcurrent Protection, Short Circuit Protection |
| Type of Trip | Thermal-Magnetic |
| Rated Breaking Capacity | 6ka |
| Rated Currents | 40A |
| Transport Package | Carton |
| Specification | 50.4*26*17 |
| Trademark | ETEK / OEM |
| Origin | Zhejiang, Prc |
| HS Code | 8536200000 |
Packaging & Delivery
Package Size50.40cm * 26.00cm * 17.00cm Package Gross Weight10.500kgProduct Description
Product DescriptionETL2-63(H) Residual Current Circuit Breaker with Overcurrent ProtectionETL2-63(H) 1P+N RCBO in 1 module width, suitable for installation in chassis distribution boards. provides comprehensive protection against short-circuits, overloads, and earth faults. This device with a blue neutral cable features a 6kA or 10kA breaking capacity and is available in rated currents up to 63A, making it suitable for residential, commercial, and industrial applications. An optional functional earth cable (white) enhances safety in the event of neutral loss. The neutral is unswitched.
1. Comprehensive ProtectionFrom basic overcurrent to sophisticated arc fault detection, ETEK products provide complete circuit protection in one cohesive product family.2. Certified QualityMeets or exceeds international standards with certifications including CE, VDE, TUV, CB, and more.3. Universal CompatibilityCompatible accessories and uniform design across the entire range enable seamless integration in distribution panels.4. Installation FriendlyDesigned with installer needs in mind, featuring clear terminals, easy access points, and compatibility with standard DIN rail systems.CertificationsTechinical Data| General Data | |
| Standard | IEC/EN 61009-1 |
| Protection | Ground fault, Overload and short-circuit |
| Type of trip | Overload and short-circuit: Thermal-magnetic, Ground fault: Electronic |
| Residual current type | AC type - AC residual current A type - residual AC and pulsating DC current |
| No. of poles | 1P+N, Neutral line is unswitched |
| Insulation voltage (Ui) | 500V |
| Rated voltage (Ue) | 230/240V~ |
| Rated currents (In) | 6, 10, 16, 20, 25, 32, 40, 50, 63A |
| Rated sensitivity current (IΔn) | 10, 30, 100, 300mA |
| Rated current off-time under (IΔn) | ≤0.1s |
| Rated residual making and breaking capacity (IΔm) | 500A (In≤50A), 10In (In>50A) |
| Rated frequency | 50/60Hz |
| Rated short-circuit capacity (Icn) | ETL2-63: 6kA; ETL2-63H: 10kA |
| Energy limiting class | 3 |
| Rated impulse withstand voltage (Uimp) (1.2/50μs) | 4kV |
| Dielectric test voltage | 2.5kV (50/60Hz, 1min.) |
| Fire resistance (glow-wire test) | 960±15°C (Enclosure); 650±10°C (Handle) |
| Thermal tripping characteristics | 1.13In No tripping within an hour; 1.45In Tripping within an hour |
| Instantaneous tripping characteristics | B: 3In-5In; C: 5In-10In |
| Electrical life | 4,000 Cycles |
| Mechanical life | 8,000 Cycles |
| Contact position indication | green OFF / red ON |
| Protection degree | IP20 |
| Ambient temperature | -25°C ~ +55°C |
| Storage temperature | -30°C ~ +70°C |
| Terminal connection type | Cable/ Pin-type/ Fork-type busbar |
| Max. terminal size for cable | Line side (bottom): 25mm²; Load side (top) : 16mm² (For 16mm² conductors: crimping terminal lug is mandatory.) |
| Max. tightening torque | Bottom (line side): 2.5N.m; Top (Load side) : 1.2N.m |
| Neutral load cable | Bule, 500mm length, 4mm² (Other lengths available upon request) |
| Functional earth cable | White, 500mm length, 0.6mm² (Other lengths available upon request) |
| Mounting type | Mounting on 35mm DIN rail |
| Incoming method | Bi-Directional |
| Tripping Sensitivity | |
| 10mA | Provides a higher level of protection for the human body and is used in certain situations with very high requirements for electric shock protection, such as children's facilities, swimming pools, bathrooms and other humid environments. |
| 30mA | This is the most commonly used protection level in homes and commercial buildings, and is suitable for socket protection in general residential environments, offices and commercial places. |
| 100mA | Usually used in situations where personal protection requirements are not as strict as 30mA, or for equipment protection such as air conditioning systems, industrial equipment, etc. |
| 300mA | Mainly used for fire protection, such as distribution boards and the general protection of large electrical equipment. |
| Tripping Characteristics | |||||||
| Curve | Rated current | Thermal Release | Magnetic Release | ||||
| Non-trip | Trip | Non-trip time | Hold current | Trip current | Trip time | ||
| B | 6-63A | 1.13In | ≤1h | 3In | ≥0.1 | ||
| 1.45In | <1h | 5In | <0.1 | ||||
| C | 6-63A | 1.13In | ≤1h | 5In | ≥0.1 | ||
| 1.45In | <1h | 10In | <0.1 | ||||
| Breaking Time of Residual Current | |||||
| In(A) | IΔn(mA) | Max. breaking time | |||
| IΔn | 2IΔn | 5IΔn | 5,10,20,50,100,200,500A | ||
| 6,10,16,20,25,32,40,50,63 | 10,30, 100, 300 | 0.1s | 0.08s | 0.04s | 0.04s |


Our Contact