| Model NO. | ETL3-63-3P+N-6A |
| Speed | Normal Type Circuit Breaker |
| Arc-extinguishing Medium | Air |
| Installation | 35mm DIN Rail |
| Structure | RCBO |
| Poles Number | 3p+N |
| Type | Circuit Breaker |
| Function | Overcurrent Protection, Short Circuit Protection |
| Type of Trip | Thermal-Magnetic |
| Rated Breaking Capacity | 6ka |
| Rated Current | 6A |
| Rated Insulation Voltage | 500V |
| Transport Package | Carton |
| Specification | 39.5*22.5*25.5 |
| Trademark | ETEK / OEM |
| Origin | Zhejiang, Prc |
Packaging & Delivery
Package Size39.50cm * 22.50cm * 25.50cm Package Gross Weight15.300kgProduct Description
Product DescriptionETL3-63(H) Residual Current Circuit Breaker with Overcurrent ProtectionETL3-63 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) provide protects against overload, short circuit, and leakage faults, supporting 230/240V (1P+N) or 400/415V (3P+N) power systems with ratings up to 63A, its reliable operation across residential and industrial applications.
1. Comprehensive ProtectionFrom basic overcurrent to sophisticated arc fault detection, ETEK products provide complete circuit protection in one cohesive product family.2. Certified QualityMeets or exceeds international standards with certifications including CE, VDE, TUV, CB, and more.3. Universal CompatibilityCompatible accessories and uniform design across the entire range enable seamless integration in distribution panels.4. Installation FriendlyDesigned with installer needs in mind, featuring clear terminals, easy access points, and compatibility with standard DIN rail systems.CertificationsTechinical Data| General Data | |
| Standard | IEC/EN 61009-1 |
| Type of trip | Ground fault, Overcurrent and short circuit |
| Ground fault: Electronic, Overload and short circuit: Thermal-magnetic | |
| Residual current type | AC type - AC residual current A type - residual AC and pulsating DC current |
| No. of poles | 1P+N, 3P+N |
| Insulation voltage (Ui) | 500V |
| Rated voltage (Ue) | 1P+N: 230/240V~; 3P+N: 400/415V~ |
| Rated currents (In) | 6, 10, 16, 20, 25, 32, 40, 50, 63A |
| Rated sensitivity current (IΔn) | 10, 30, 100, 300mA |
| Rated current off-time under (IΔn) | <0.3s |
| Rated residual making and breaking capacity (IΔm) | 500A (In≤50A), 10In (In>50A) |
| Rated frequency | 50/60Hz |
| Rated short-circuit capacity (Icn) | ETL3-63: 6kA, ETL3-63H: 10kA |
| Energy limiting class | 3 |
| Rated impulse withstand voltage (Uimp) (1.2/50μs) | 4kV |
| Dielectric test voltage | 2.5kV (50/60Hz, 1min.) |
| Fire resistance (glow-wire test) | 960±15°C (Enclosure); 650±10°C (Handle) |
| Thermal tripping characteristics | 1.13In No tripping within an hour; 1.45In Tripping within an hour |
| Instantaneous tripping characteristics | B: 3In-5In; C: 5In-10In |
| Electrical life | 4,000 Cycles |
| Mechanical life | 8,000 Cycles |
| Contact position indication | green OFF / red ON |
| Ground fault indicator | White: Normal / Blue: Leakage fault |
| Protection degree | IP20 |
| Ambient temperature | -25°C ~ +55°C |
| Storage temperature | -30°C ~ +70°C |
| Terminal connection type | Cable/ Pin-type/ Fork-type busbar |
| Max. terminal size for cable | 16mm² flexible/ 25mm² rigid |
| Max. tightening torque | 2.5N.m |
| Mounting type | Mounting on 35mm DIN rail |
| Incoming method | Bi-Directional |
| Tripping Sensitivity | |
| 10mA | Provides a higher level of protection for the human body and is used in certain situations with very high requirements for electric shock protection, such as children's facilities, swimming pools, bathrooms and other humid environments. |
| 30mA | This is the most commonly used protection level in homes and commercial buildings, and is suitable for socket protection in general residential environments, offices and commercial places. |
| 100mA | Usually used in situations where personal protection requirements are not as strict as 30mA, or for equipment protection such as air conditioning systems, industrial equipment, etc. |
| 300mA | Mainly used for fire protection, such as distribution boards and the general protection of large electrical equipment. |
| Tripping Characteristics | |||||||
| Curve | Rated current | Thermal Release | Magnetic Release | ||||
| Non-trip | Trip | Non-trip time | Hold current | Trip current | Trip time | ||
| B | 6-63A | 1.13In | ≤1h | 3In | ≥0.1 | ||
| 1.45In | <1h | 5In | <0.1 | ||||
| C | 6-63A | 1.13In | ≤1h | 5In | ≥0.1 | ||
| 1.45In | <1h | 10In | <0.1 | ||||
| Breaking Time of Residual Current | |||||
| In(A) | IΔn(mA) | Max. breaking time | |||
| IΔn | 2IΔn | 5IΔn | 5,10,20,50,100,200,500A | ||
| 6,10,16,20,25,32,40,50,63 | 10, 30, 100, 300 | 0.1s | 0.08s | 0.04s | 0.04s |